Gülmar-made laminate-faced panels and curved profiles, plus raw plywood supply.
Short answer: Interior compact laminate wall cladding follows a few core rules: leave enough expansion room for the sheet to move with humidity and temperature, keep a ventilated air space behind the panels, use a single fixed point near the center of each panel, and make every other fixing a sliding point with an oversized hole. The exact gaps and clearances follow the product data sheet, the panel size and the fixing-system instructions.
Compact laminate wall cladding goes where impact, moisture, and frequent cleaning all show up at once: hospital corridors, schools, locker rooms, and wet areas. The material is tough, but it is not installed like tile or drywall. Compact panels move with humidity and temperature, and an installation that ignores that movement ends up with closed joints, bowed panels, or cracks starting at screw holes. This guide walks through the installation rules with their numbers and sources, and shows how they play out on site.
Definition: Compact laminate is a high-pressure laminate (HPL) sheet classified under EN 438-4, produced in thicknesses above 2 mm and generally self-supporting above 5 mm (ICDLI). The interior grade is designated CGS. G-COM compact laminate, which we use on our projects, belongs to this class; its data sheet lists a density of 1.4 g/cm³ against a 1.35 g/cm³ minimum.
ICDLI, the umbrella body of European decorative laminate manufacturers, lists wet rooms, hospitals, operating rooms, pharmacies, schools, laboratories, sports facilities and pools, hotels and restaurants, and subway stations among the indoor applications for compact sheets. The projects we see most often are:
For a wider look at surface selection in healthcare, see our article on compact surfaces in labs and healthcare.
The core of a compact panel is resin-impregnated kraft paper, which makes it a fiber-based material. The Composite Panel Association's bulletin on dimensional stability notes that wood-based laminating materials, including resin-impregnated papers and HPL, gain and lose water as relative humidity changes, and that the resulting expansion or contraction tracks the change in moisture content. The same bulletin explains how a panel warps when its two faces are not kept in balance.
The ICDLI leaflet on processing compact laminates draws two practical conclusions:
To put a number on the movement, look at the G-COM data sheet. In the EN 438-2 Part 17 dimensional stability test at elevated temperature, G-COM 5 mm and thicker changed by 0.18% lengthwise and 0.23% crosswise (limits: 0.3% and 0.6%). On a 3,050 mm panel, 0.23% works out to about 7 mm. That is a severe test condition, and movement in a conditioned building is usually smaller, but it shows clearly why joints and holes need clearance. For comparison, the data sheet lists a linear thermal expansion coefficient of 6.0×10⁻⁶ per °C, so a 20 °C temperature swing stretches the same panel by only about 0.4 mm. Humidity and the climate difference across the panel are what really drive movement.
The rules below come from the processing leaflet of ICDLI, the European laminate industry association, and from the G-COM data sheet. Dimensions such as expansion gaps, fixing spacing and floor or ceiling clearance depend on the product data sheet, the panel size and the fixing-system instructions, so treat this table as a starting checklist.
| Rule | Value / practice | Source |
|---|---|---|
| Expansion gap | Enough room for the sheet to expand and contract; size depends on panel length and the fixing system | ICDLI, section 5.2 |
| Dimensional movement (data) | 0.18% lengthwise and 0.23% crosswise in the 70 °C test, sheets 5 mm and thicker | G-COM data sheet (EN 438-2 part 17) |
| Rear ventilation | Sufficient air circulation behind the panels | ICDLI, section 5.2 |
| Fixed and sliding points | Fixed point near the center of the panel; all other fixings are sliding points | ICDLI, section 5.2 (figure 7) |
| Sliding-point holes | For fixings that pass through the panel, holes 2–3 mm larger than the fastener; elastic sleeves are an alternative | ICDLI, section 5.4.3 |
| Concealed screws on rigid substructures | Clearance holes, shims or slip film | ICDLI, section 5.2.3 |
| Production direction | Panels that are bonded or joined together run in the same direction | ICDLI, sections 5 and 5.1.3 |
| Substructure | Sturdy, well aligned, tension-free, level and firmly fixed to the wall; protected against corrosion and rot | ICDLI, section 5.2 |
| Fasteners | Corrosion-resistant wherever moisture is present | ICDLI, section 5 |
| Panel thickness | Usually self-supporting above 5 mm; thickness and substructure together set the stability of the cladding | ICDLI, sections 1 and 5.2 |
| Storage | Closed storage at 18–23 °C and 50–60% relative humidity, maintained after sheets are taken from the stack | ICDLI, section 3.2 |
All three methods below are used:
The fixed point sits near the center so the panel expands evenly in every direction. Every other fixing is a sliding point: the screw sits in an oversized hole that lets the panel move around it. The diagram shows an elevation and a section side by side:
Rough worked example: On a 3,050 mm panel with the fixed point at the center, the farthest edge is about 1.5 m away. The 0.23% crosswise change measured in the severe 70 °C test in the G-COM data sheet works out to roughly 3.5 mm over that distance; movement on site is usually smaller. ICDLI recommends holes 2–3 mm larger than the fastener for fixings that pass through the panel. The screw head or washer must fully cover that hole. Exact hole sizes and fixing spacing depend on panel thickness and the fixing-system manufacturer's table.
The compact laminate surface itself is highly water-resistant; in wet rooms, trouble usually comes from the details. These are the rules we follow in wet rooms:
Toilet and shower partitions have their own details (legs, floor clearance, doors). We cover the cubicle side in material selection for compact WC cubicle systems.
Compact laminate is dense and hard, so cutting and drilling it on site is tough on both tools and quality. The bigger risk is geometry. Processing rules from the ICDLI leaflet and from our own shop floor:
That is why the safest route is to have fixed and sliding holes, outlet cutouts, and radii cut on a CNC to your layout. See our CNC services, and our guide to measurements, holes, and edge details in CNC-cut panel projects for how to prepare a hole plan.
The G-COM data sheet includes surface resistance tests with chlorine, hydrogen peroxide, and common antiseptics. These were run with Gentaş's in-house test method, not an EN standard: five drops of the test solution go on the surface under a watch glass, and after the exposure time the area is rinsed with plenty of water, wiped dry, and rated on a 0–4 scale. Level 0 means no change detectable with the naked eye.
| Reagent | Concentration | Exposure time | Result |
|---|---|---|---|
| Chlorine (water-based solution) | 1,000 and 10,000 ppm | 1, 2, 4, 8, 12, 24 hours | Level 0 (8 mm, solid and printed decors) |
| Hydrogen peroxide | 30% | 12 and 24 hours | Level 0 (4 mm, matte) |
| Benzalkonium chloride | 4% | 12 and 24 hours | Level 0 |
| Benzethonium chloride | 2% | 12 and 24 hours | Level 0 |
| Domiphen bromide | 4% | 12 and 24 hours | Level 0 |
| Isopropyl alcohol | 70% | 12 and 24 hours | Level 0 |
Source: Gentaş G-COM technical data sheet (Gentaş in-house test method). If your disinfectant or contact time differs, we recommend testing it on a small sample first.
For routine cleaning, ICDLI's HPL cleaning leaflet recommends water and a soft cloth, plus a non-abrasive cleaner when needed, and advises against prolonged contact with aggressive acidic cleaners. For hard-water scale it suggests a warm 10% acetic or citric acid solution followed by a hot-water rinse. A non-porous surface is easy to clean with a proper disinfection protocol, but which products are used, and how often, is a decision for the facility's infection-control team. We look at what antimicrobial additives do and do not add in antibacterial and antimicrobial surfaces.
According to the G-COM data sheet, the EN 13501-1 reaction-to-fire class depends on thickness: B-s1,d0 at 12–25 mm, C-s1,d0 at 8–10 mm, and D-s1,d0 at 3–8 mm. Under the EN 13501-1 class definitions, Class B products do not lead to flashover but do contribute to a fully developed fire, while the s and d ratings are additional classes for smoke production and flaming droplets or particles. A classification applies to the mounting and fixing condition that was tested, so the mounting described in the test report should match the installation on site.
The class required in corridors and escape routes is set by the applicable building and fire code and by the project's design professional. Our article on fire-retardant laminate and compact panels explains what the classes mean.
Three things drive thickness: batten spacing, expected impact, and the required fire class. ICDLI notes that compact sheets are generally self-supporting above 5 mm, and that the stability of cladding depends on the substructure and the sheet thickness together. If the project calls for B-s1,d0, the G-COM data sheet puts you at 12 mm or thicker. We confirm which thicknesses are in stock for your project at the quote stage.
We have been based in Bornova, İzmir, since 1998 and have been a Gentaş main dealer since 2020, with more than 1,200 completed projects. A wall cladding job usually runs like this:
Browse the decor and color options to pick a finish. Send your measurements and drawings over WhatsApp and we will prepare the quote there.
Last updated: 2026-11
There is no single universal value. The sheet changes dimension with humidity and temperature; in the 70 °C dimensional stability test in the G-COM data sheet, sheets 5 mm and thicker changed by 0.18% lengthwise and 0.23% crosswise. That movement is taken up at joints, at floor and ceiling terminations, and in the sliding-point holes; ICDLI recommends holes 2–3 mm larger than the fastener for fixings that pass through the panel. The exact allowance comes from the product data sheet and the fixing-system instructions.
All three methods are used: visible fixing with screws or rivets, concealed fixing on hanging rails, and concealed bonding with permanently elastic adhesive systems made for the job. Whatever the method, the panel must be free to move. That rules out rigid full-surface gluing to a flat wall; screwed systems use one central fixed point and sliding points with oversized holes.
The front of the panel faces room air while the back faces the wall. If humidity and temperature differ across the two faces, the panel can bow. ICDLI therefore calls for sufficient ventilation behind the panels, and air inlets and outlets should be left open.
Yes. The surface is highly water-resistant and is widely used in showers and wet rooms. The details are what matter: panels should not be exposed to standing water, the room needs good ventilation, and fasteners must be corrosion-resistant. The panel does not sit directly on the floor; the expansion gap is closed with an elastic joint. Inside corners are sealed the same way.
ICDLI notes that compact sheets are generally self-supporting above 5 mm, and that the substructure and the sheet thickness together set the stability of the cladding. The fire requirement can be decisive: per the G-COM data sheet, the B-s1,d0 class applies to 12–25 mm thicknesses. Batten spacing and expected impact also factor in. Available stock thicknesses are confirmed for each project at the quote stage.
Under Gentaş's in-house test method in the G-COM data sheet, 1,000 and 10,000 ppm chlorine, 30% hydrogen peroxide, 4% benzalkonium chloride, and 70% isopropyl alcohol all rated level 0 after 24 hours of contact, meaning no change visible to the naked eye. This is not an EN standard test. Test your own product and contact time on a sample; the facility's infection-control team sets the protocol.